Outdoor Tripolar Horizontal & Vertical

  • Rated Voltage : 12-24-36KV (Medium Voltage Product)

  • Rated Current : 400-630A

SALIENT FEATURES

  • All mounting accessories are part of Isolator.No extra hardware required for installation.

  • Can be installed without special tools and tackles, in less time.

  • Can be mounted on single pole resulting in reduction in cost and saying in space.

  • Quick make and break manual operation.

  • High contact life, can be used for On-load operation.

  • Unique contact design to ensure proper contacts resulting in reduced power losses.

  • Quality as per international standards.

outdoor tripolar vertical and horizontal mounting isolators.png

FAQs

What is 33 KV Isolator ?

1 The 33 KV isolator shall be outdoor type, three phase, double break, center rotating type suitable for manual operation. All isolators as given in the schedule of requirements shall be suitable for horizontal upright mounting on structure or P.C.C. pole structures.

What is the function of isolator?

An isolator is a device used for isolating a circuit or equipment from a source of power. An isolator is a mechanical switching device that, in the open position, allows for isolation of the input and output of a device.

Does isolator have current rating?

Isolator switches are designed with maximum current ratings - i.e. the highest level of current at which they will operate safely. This can range from as little as six amps up to 200 amps, via mid-range models between 20A and 50A.

Do isolator switches have fuses?

An isolator is an isolator, and a fuse is a fuse. Most bathroom fans are run of the lighting circuit, the fan isolator is a three pole device so that fans with timer functions that have a permanent live supply can be safely isolated for servicing.

What is a High-Voltage isolator?

High-voltage isolation switches are used in electrical substations to allow isolation of apparatus such as circuit breakers, transformers, and transmission lines, for maintenance. ... In some designs, the isolator switch has the additional ability to earth the isolated circuit thereby providing additional safety.

isolators in 33/11 kv substation ?

For 33 kV, horizontal type isolating switches are used. The rated normal current is 630 A at 36 kV. For 11 kV, both horizontal and vertical mounting isolating switches of 400 Amps at 12 kV are used. Earthing switches are provided at various locations to facilitate maintenance.

​

​

​